Reserves: Update docs
This commit is contained in:
11
CHANGELOG.md
11
CHANGELOG.md
@@ -11,6 +11,17 @@ All notable changes to this project will be documented in this file.
|
|||||||
[semver]: https://semver.org/spec/v2.0.0.html
|
[semver]: https://semver.org/spec/v2.0.0.html
|
||||||
[pkjjl]: https://pkgdocs.julialang.org/v1/compatibility/#compat-pre-1.0
|
[pkjjl]: https://pkgdocs.julialang.org/v1/compatibility/#compat-pre-1.0
|
||||||
|
|
||||||
|
## [Unreleased]
|
||||||
|
### Added
|
||||||
|
- Add multiple reserve products
|
||||||
|
|
||||||
|
### Changed
|
||||||
|
- To support multiple reserve products, the input data format has been modified as follows:
|
||||||
|
- In `Generators`, replace `Provides spinning reserves?` by `Reserve eligibility`
|
||||||
|
- In `Parameters`, remove `Reserve shortfall penalty`
|
||||||
|
- Revise `Reserves` section
|
||||||
|
|
||||||
|
|
||||||
## [0.2.2] - 2021-07-21
|
## [0.2.2] - 2021-07-21
|
||||||
### Fixed
|
### Fixed
|
||||||
- Fix small bug in validation scripts related to startup costs
|
- Fix small bug in validation scripts related to startup costs
|
||||||
|
|||||||
@@ -2,7 +2,7 @@ name = "UnitCommitment"
|
|||||||
uuid = "64606440-39ea-11e9-0f29-3303a1d3d877"
|
uuid = "64606440-39ea-11e9-0f29-3303a1d3d877"
|
||||||
authors = ["Santos Xavier, Alinson <axavier@anl.gov>"]
|
authors = ["Santos Xavier, Alinson <axavier@anl.gov>"]
|
||||||
repo = "https://github.com/ANL-CEEESA/UnitCommitment.jl"
|
repo = "https://github.com/ANL-CEEESA/UnitCommitment.jl"
|
||||||
version = "0.2.2"
|
version = "0.3.0"
|
||||||
|
|
||||||
[deps]
|
[deps]
|
||||||
DataStructures = "864edb3b-99cc-5e75-8d2d-829cb0a9cfe8"
|
DataStructures = "864edb3b-99cc-5e75-8d2d-829cb0a9cfe8"
|
||||||
|
|||||||
@@ -35,7 +35,6 @@ This section describes system-wide parameters, such as power balance and reserve
|
|||||||
| `Time horizon (h)` | Length of the planning horizon (in hours). | Required | N
|
| `Time horizon (h)` | Length of the planning horizon (in hours). | Required | N
|
||||||
| `Time step (min)` | Length of each time step (in minutes). Must be a divisor of 60 (e.g. 60, 30, 20, 15, etc). | `60` | N
|
| `Time step (min)` | Length of each time step (in minutes). Must be a divisor of 60 (e.g. 60, 30, 20, 15, etc). | `60` | N
|
||||||
| `Power balance penalty ($/MW)` | Penalty for system-wide shortage or surplus in production (in $/MW). This is charged per time step. For example, if there is a shortage of 1 MW for three time steps, three times this amount will be charged. | `1000.0` | Y
|
| `Power balance penalty ($/MW)` | Penalty for system-wide shortage or surplus in production (in $/MW). This is charged per time step. For example, if there is a shortage of 1 MW for three time steps, three times this amount will be charged. | `1000.0` | Y
|
||||||
| `Reserve shortfall penalty ($/MW)` | Penalty for system-wide shortage in meeting reserve requirements (in $/MW). This is charged per time step. Negative value implies reserve constraints must always be satisfied. | `-1` | Y
|
|
||||||
|
|
||||||
|
|
||||||
#### Example
|
#### Example
|
||||||
@@ -44,7 +43,6 @@ This section describes system-wide parameters, such as power balance and reserve
|
|||||||
"Parameters": {
|
"Parameters": {
|
||||||
"Time horizon (h)": 4,
|
"Time horizon (h)": 4,
|
||||||
"Power balance penalty ($/MW)": 1000.0,
|
"Power balance penalty ($/MW)": 1000.0,
|
||||||
"Reserve shortfall penalty ($/MW)": -1.0
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
```
|
```
|
||||||
@@ -96,7 +94,7 @@ This section describes all generators in the system, including thermal units, re
|
|||||||
| `Initial status (h)` | If set to a positive number, indicates the amount of time (in hours) the generator has been on at the beginning of the simulation, and if set to a negative number, the amount of time the generator has been off. For example, if `Initial status (h)` is `-2`, this means that the generator was off since `-02:00` (h:min). The simulation starts at time `00:00`. If `Initial status (h)` is `3`, this means that the generator was on since `-03:00`. A value of zero is not acceptable. | Required | N
|
| `Initial status (h)` | If set to a positive number, indicates the amount of time (in hours) the generator has been on at the beginning of the simulation, and if set to a negative number, the amount of time the generator has been off. For example, if `Initial status (h)` is `-2`, this means that the generator was off since `-02:00` (h:min). The simulation starts at time `00:00`. If `Initial status (h)` is `3`, this means that the generator was on since `-03:00`. A value of zero is not acceptable. | Required | N
|
||||||
| `Initial power (MW)` | Amount of power the generator at time step `-1`, immediately before the planning horizon starts. | Required | N
|
| `Initial power (MW)` | Amount of power the generator at time step `-1`, immediately before the planning horizon starts. | Required | N
|
||||||
| `Must run?` | If `true`, the generator should be committed, even if that is not economical (Boolean). | `false` | Y
|
| `Must run?` | If `true`, the generator should be committed, even if that is not economical (Boolean). | `false` | Y
|
||||||
| `Provides spinning reserves?` | If `true`, this generator may provide spinning reserves (Boolean). | `true` | Y
|
| `Reserve eligibility` | List of reserve products this generator is eligibe to provide. By default, the generator is not eligible to provide any reserves. | `[]` | N
|
||||||
|
|
||||||
#### Production costs and limits
|
#### Production costs and limits
|
||||||
|
|
||||||
@@ -135,13 +133,13 @@ Note that this curve also specifies the production limits. Specifically, the fir
|
|||||||
"Minimum uptime (h)": 4,
|
"Minimum uptime (h)": 4,
|
||||||
"Initial status (h)": 12,
|
"Initial status (h)": 12,
|
||||||
"Must run?": false,
|
"Must run?": false,
|
||||||
"Provides spinning reserves?": true,
|
"Reserve eligibility": ["r1"],
|
||||||
},
|
},
|
||||||
"gen2": {
|
"gen2": {
|
||||||
"Bus": "b5",
|
"Bus": "b5",
|
||||||
"Production cost curve (MW)": [0.0, [10.0, 8.0, 0.0, 3.0]],
|
"Production cost curve (MW)": [0.0, [10.0, 8.0, 0.0, 3.0]],
|
||||||
"Production cost curve ($)": [0.0, 0.0],
|
"Production cost curve ($)": [0.0, 0.0],
|
||||||
"Provides spinning reserves?": true,
|
"Reserve eligibility": ["r1", "r2"],
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
@@ -206,24 +204,30 @@ This section describes the characteristics of transmission system, such as its t
|
|||||||
|
|
||||||
### Reserves
|
### Reserves
|
||||||
|
|
||||||
This section describes the hourly amount of operating reserves required.
|
This section describes the hourly amount of reserves required.
|
||||||
|
|
||||||
|
|
||||||
| Key | Description | Default | Time series?
|
| Key | Description | Default | Time series?
|
||||||
| :-------------------- | :------------------------------------------------- | --------- | :----:
|
| :-------------------- | :------------------------------------------------- | --------- | :----:
|
||||||
| `Spinning (MW)` | Minimum amount of system-wide spinning reserves (in MW). Only generators which are online may provide this reserve. | `0.0` | Y
|
| `Type` | Type of reserve product. Currently, only `Spinning` is supported. | Required | N
|
||||||
|
| `Amount (MW)` | Amount of reserves required. | Required | Y
|
||||||
|
| `Shortfall penalty ($/MW)` | Penalty for shortage in meeting the reserve requirements (in $/MW). This is charged per time step. Negative value implies reserve constraints must always be satisfied. | `-1` | Y
|
||||||
|
|
||||||
#### Example
|
#### Example
|
||||||
|
|
||||||
```json
|
```json
|
||||||
{
|
{
|
||||||
"Reserves": {
|
"Reserves": {
|
||||||
"Spinning (MW)": [
|
"r1": {
|
||||||
|
"Type": "Spinning",
|
||||||
|
"Amount (MW)": [
|
||||||
57.30552,
|
57.30552,
|
||||||
53.88429,
|
53.88429,
|
||||||
51.31838,
|
51.31838,
|
||||||
50.46307
|
50.46307
|
||||||
]
|
],
|
||||||
|
"Shortfall penalty ($/MW)": 5.0
|
||||||
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
```
|
```
|
||||||
@@ -286,9 +290,6 @@ The output data format is also JSON-based, but it is not currently documented si
|
|||||||
Current limitations
|
Current limitations
|
||||||
-------------------
|
-------------------
|
||||||
|
|
||||||
* All reserves are system-wide. Zonal reserves are not currently supported.
|
|
||||||
* Network topology remains the same for all time periods
|
* Network topology remains the same for all time periods
|
||||||
* Only N-1 transmission contingencies are supported. Generator contingencies are not currently supported.
|
* Only N-1 transmission contingencies are supported. Generator contingencies are not currently supported.
|
||||||
* Time-varying minimum production amounts are not currently compatible with ramp/startup/shutdown limits.
|
* Time-varying minimum production amounts are not currently compatible with ramp/startup/shutdown limits.
|
||||||
|
|
||||||
|
|
||||||
|
|||||||