### Storage units
This section describes energy storage units in the system which charge and discharge power. The storage units consume power while charging, and generate power while discharging.
| Key | Description | Default | Time series? | Uncertain?
| :---------------- | :------------------------------------------------ | :------: | :------------: | :----:
| `Bus` | Bus where the storage unit is located. Multiple storage units may be placed at the same bus. | Required | No | Yes
| `Minimum level (MWh)` | Minimum of energy level this storage unit may contain. | `0.0` | Yes | Yes
| `Maximum level (MWh)` | Maximum of energy level this storage unit may contain. | Required | Yes | Yes
| `Allow simultaneous charging and discharging` | If `false`, the storage unit is not allowed to charge and discharge at the same time (Boolean). | `true` | Yes | Yes
| `Charge cost ($/MW)` | Cost incurred for charging each MW of power into this storage unit. | Required | Yes | Yes
| `Discharge cost ($/MW)` | Cost incurred for discharging each MW of power from this storage unit. | Required | Yes | Yes
| `Charge efficiency` | Efficiency rate to charge power into this storage unit. This value must be greater than or equal to `0.0`, and less than or equal to `1.0`. | `1.0` | Yes | Yes
| `Discharge efficiency` | Efficiency rate to discharge power from this storage unit. This value must be greater than or equal to `0.0`, and less than or equal to `1.0`. | `1.0` | Yes | Yes
| `Loss factor` | The energy dissipation rate of this storage unit. This value must be greater than or equal to `0.0`, and less than or equal to `1.0`. | `0.0` | Yes | Yes
| `Minimum charge rate (MW)` | Minimum amount of power rate this storage unit may charge. | `0.0` | Yes | Yes
| `Maximum charge rate (MW)` | Maximum amount of power rate this storage unit may charge. | Required | Yes | Yes
| `Minimum discharge rate (MW)` | Minimum amount of power rate this storage unit may discharge. | `0.0` | Yes | Yes
| `Maximum discharge rate (MW)` | Maximum amount of power rate this storage unit may discharge. | Required | Yes | Yes
| `Initial level (MWh)` | Amount of energy this storage unit at time step `-1`, immediately before the planning horizon starts. | `0.0` | No | Yes
| `Last period minimum level (MWh)` | Minimum of energy level this storage unit may contain in the last time step. By default, this value is the same as the last value of `Minimum level (MWh)`. | `Minimum level (MWh)` | No | Yes
| `Last period maximum level (MWh)` | Maximum of energy level this storage unit may contain in the last time step. By default, this value is the same as the last value of `Maximum level (MWh)`. | `Maximum level (MWh)` | No | Yes
#### Example
```json
{
"Storage units": {
"su1": {
"Bus": "b2",
"Maximum level (MWh)": 100.0,
"Charge cost ($/MW)": 2.0,
"Discharge cost ($/MW)": 2.5,
"Maximum charge rate (MW)": 10.0,
"Maximum discharge rate (MW)": 8.0
},
"su2": {
"Bus": "b2",
"Minimum level (MWh)": 10.0,
"Maximum level (MWh)": 100.0,
"Allow simultaneous charging and discharging": false,
"Charge cost ($/MW)": 3.0,
"Discharge cost ($/MW)": 3.5,
"Charge efficiency": 0.8,
"Discharge efficiency": 0.85,
"Loss factor": 0.01,
"Minimum charge rate (MW)": 5.0,
"Maximum charge rate (MW)": 10.0,
"Minimum discharge rate (MW)": 2.0,
"Maximum discharge rate (MW)": 10.0,
"Initial level (MWh)": 70.0,
"Last period minimum level (MWh)": 80.0,
"Last period maximum level (MWh)": 85.0
},
"su3": {
"Bus": "b9",
"Minimum level (MWh)": [10.0, 11.0, 12.0, 13.0],
"Maximum level (MWh)": [100.0, 110.0, 120.0, 130.0],
"Allow simultaneous charging and discharging": [false, false, true, true],
"Charge cost ($/MW)": [2.0, 2.1, 2.2, 2.3],
"Discharge cost ($/MW)": [1.0, 1.1, 1.2, 1.3],
"Charge efficiency": [0.8, 0.81, 0.82, 0.82],
"Discharge efficiency": [0.85, 0.86, 0.87, 0.88],
"Loss factor": [0.01, 0.01, 0.02, 0.02],
"Minimum charge rate (MW)": [5.0, 5.1, 5.2, 5.3],
"Maximum charge rate (MW)": [10.0, 10.1, 10.2, 10.3],
"Minimum discharge rate (MW)": [4.0, 4.1, 4.2, 4.3],
"Maximum discharge rate (MW)": [8.0, 8.1, 8.2, 8.3],
"Initial level (MWh)": 20.0,
"Last period minimum level (MWh)": 21.0,
"Last period maximum level (MWh)": 22.0
}
}
}
```
### Price-sensitive loads ### Price-sensitive loads
This section describes components in the system which may increase or reduce their energy consumption according to the energy prices. Fixed loads (as described in the `buses` section) are always served, regardless of the price, unless there is significant congestion in the system or insufficient production capacity. Price-sensitive loads, on the other hand, are only served if it is economical to do so. This section describes components in the system which may increase or reduce their energy consumption according to the energy prices. Fixed loads (as described in the `buses` section) are always served, regardless of the price, unless there is significant congestion in the system or insufficient production capacity. Price-sensitive loads, on the other hand, are only served if it is economical to do so.