mirror of
https://github.com/ANL-CEEESA/UnitCommitment.jl.git
synced 2025-12-06 00:08:52 -06:00
Compare commits
9 Commits
feature/ne
...
feature/fi
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
5afb2363af | ||
|
|
860c47b7e3 | ||
|
|
37b21853be | ||
|
|
c8c7350096 | ||
|
|
7302fabe37 | ||
|
|
4ed13d6e95 | ||
| b1498c50b3 | |||
|
|
000215e991 | ||
| 7a1b6f0f55 |
4
.github/workflows/test.yml
vendored
4
.github/workflows/test.yml
vendored
@@ -9,8 +9,8 @@ jobs:
|
|||||||
runs-on: ${{ matrix.os }}
|
runs-on: ${{ matrix.os }}
|
||||||
strategy:
|
strategy:
|
||||||
matrix:
|
matrix:
|
||||||
julia-version: ['1.3', '1.4', '1.5', '1.6']
|
julia-version: ['1.4', '1.5', '1.6']
|
||||||
julia-arch: [x64, x86]
|
julia-arch: [x64]
|
||||||
os: [ubuntu-latest, windows-latest, macOS-latest]
|
os: [ubuntu-latest, windows-latest, macOS-latest]
|
||||||
exclude:
|
exclude:
|
||||||
- os: macOS-latest
|
- os: macOS-latest
|
||||||
|
|||||||
@@ -11,9 +11,10 @@ All notable changes to this project will be documented in this file.
|
|||||||
[semver]: https://semver.org/spec/v2.0.0.html
|
[semver]: https://semver.org/spec/v2.0.0.html
|
||||||
[pkjjl]: https://pkgdocs.julialang.org/v1/compatibility/#compat-pre-1.0
|
[pkjjl]: https://pkgdocs.julialang.org/v1/compatibility/#compat-pre-1.0
|
||||||
|
|
||||||
## [0.2.2] - Unreleased
|
## [0.2.2] - 2021-07-21
|
||||||
### Fixed
|
### Fixed
|
||||||
- Fix small bug in validation scripts related to startup costs
|
- Fix small bug in validation scripts related to startup costs
|
||||||
|
- Fix duplicated startup constraints (@mtanneau, #12)
|
||||||
|
|
||||||
## [0.2.1] - 2021-06-02
|
## [0.2.1] - 2021-06-02
|
||||||
### Added
|
### Added
|
||||||
|
|||||||
@@ -28,13 +28,14 @@ Each section is described in detail below. For a complete example, see [case14](
|
|||||||
|
|
||||||
### Parameters
|
### Parameters
|
||||||
|
|
||||||
This section describes system-wide parameters, such as power balance penalties, optimization parameters, such as the length of the planning horizon and the time.
|
This section describes system-wide parameters, such as power balance and reserve shortfall penalties, and optimization parameters, such as the length of the planning horizon and the time.
|
||||||
|
|
||||||
| Key | Description | Default | Time series?
|
| Key | Description | Default | Time series?
|
||||||
| :----------------------------- | :------------------------------------------------ | :------: | :------------:
|
| :----------------------------- | :------------------------------------------------ | :------: | :------------:
|
||||||
| `Time horizon (h)` | Length of the planning horizon (in hours). | Required | N
|
| `Time horizon (h)` | Length of the planning horizon (in hours). | Required | N
|
||||||
| `Time step (min)` | Length of each time step (in minutes). Must be a divisor of 60 (e.g. 60, 30, 20, 15, etc). | `60` | N
|
| `Time step (min)` | Length of each time step (in minutes). Must be a divisor of 60 (e.g. 60, 30, 20, 15, etc). | `60` | N
|
||||||
| `Power balance penalty ($/MW)` | Penalty for system-wide shortage or surplus in production (in $/MW). This is charged per time step. For example, if there is a shortage of 1 MW for three time steps, three times this amount will be charged. | `1000.0` | Y
|
| `Power balance penalty ($/MW)` | Penalty for system-wide shortage or surplus in production (in $/MW). This is charged per time step. For example, if there is a shortage of 1 MW for three time steps, three times this amount will be charged. | `1000.0` | Y
|
||||||
|
| `Reserve shortfall penalty ($/MW)` | Penalty for system-wide shortage in meeting reserve requirements (in $/MW). This is charged per time step. Negative value implies reserve constraints must always be satisfied. | `-1` | Y
|
||||||
|
|
||||||
|
|
||||||
#### Example
|
#### Example
|
||||||
@@ -42,7 +43,8 @@ This section describes system-wide parameters, such as power balance penalties,
|
|||||||
{
|
{
|
||||||
"Parameters": {
|
"Parameters": {
|
||||||
"Time horizon (h)": 4,
|
"Time horizon (h)": 4,
|
||||||
"Power balance penalty ($/MW)": 1000.0
|
"Power balance penalty ($/MW)": 1000.0,
|
||||||
|
"Reserve shortfall penalty ($/MW)": -1.0
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
```
|
```
|
||||||
|
|||||||
Binary file not shown.
@@ -98,6 +98,10 @@ function _from_json(json; repair = true)
|
|||||||
json["Parameters"]["Power balance penalty (\$/MW)"],
|
json["Parameters"]["Power balance penalty (\$/MW)"],
|
||||||
default = [1000.0 for t in 1:T],
|
default = [1000.0 for t in 1:T],
|
||||||
)
|
)
|
||||||
|
shortfall_penalty = timeseries(
|
||||||
|
json["Parameters"]["Reserve shortfall penalty (\$/MW)"],
|
||||||
|
default = [-1.0 for t in 1:T],
|
||||||
|
)
|
||||||
|
|
||||||
# Read buses
|
# Read buses
|
||||||
for (bus_name, dict) in json["Buses"]
|
for (bus_name, dict) in json["Buses"]
|
||||||
@@ -264,6 +268,7 @@ function _from_json(json; repair = true)
|
|||||||
instance = UnitCommitmentInstance(
|
instance = UnitCommitmentInstance(
|
||||||
T,
|
T,
|
||||||
power_balance_penalty,
|
power_balance_penalty,
|
||||||
|
shortfall_penalty,
|
||||||
units,
|
units,
|
||||||
buses,
|
buses,
|
||||||
lines,
|
lines,
|
||||||
|
|||||||
@@ -72,6 +72,8 @@ end
|
|||||||
mutable struct UnitCommitmentInstance
|
mutable struct UnitCommitmentInstance
|
||||||
time::Int
|
time::Int
|
||||||
power_balance_penalty::Vector{Float64}
|
power_balance_penalty::Vector{Float64}
|
||||||
|
"Penalty for failing to meet reserve requirement."
|
||||||
|
shortfall_penalty::Vector{Float64}
|
||||||
units::Vector{Unit}
|
units::Vector{Unit}
|
||||||
buses::Vector{Bus}
|
buses::Vector{Bus}
|
||||||
lines::Vector{TransmissionLine}
|
lines::Vector{TransmissionLine}
|
||||||
|
|||||||
@@ -2,6 +2,12 @@
|
|||||||
# Copyright (C) 2020, UChicago Argonne, LLC. All rights reserved.
|
# Copyright (C) 2020, UChicago Argonne, LLC. All rights reserved.
|
||||||
# Released under the modified BSD license. See COPYING.md for more details.
|
# Released under the modified BSD license. See COPYING.md for more details.
|
||||||
|
|
||||||
|
"""
|
||||||
|
_add_status_vars!
|
||||||
|
|
||||||
|
Adds symbols identified by `Gar1962.StatusVars` to `model`.
|
||||||
|
Fix variables if a certain generator _must_ run or based on initial conditions.
|
||||||
|
"""
|
||||||
function _add_status_vars!(
|
function _add_status_vars!(
|
||||||
model::JuMP.Model,
|
model::JuMP.Model,
|
||||||
g::Unit,
|
g::Unit,
|
||||||
@@ -10,15 +16,93 @@ function _add_status_vars!(
|
|||||||
is_on = _init(model, :is_on)
|
is_on = _init(model, :is_on)
|
||||||
switch_on = _init(model, :switch_on)
|
switch_on = _init(model, :switch_on)
|
||||||
switch_off = _init(model, :switch_off)
|
switch_off = _init(model, :switch_off)
|
||||||
|
FIX_VARS = !formulation_status_vars.fix_vars_via_constraint
|
||||||
|
is_initially_on = _is_initially_on(g) > 0
|
||||||
for t in 1:model[:instance].time
|
for t in 1:model[:instance].time
|
||||||
if g.must_run[t]
|
|
||||||
is_on[g.name, t] = 1.0
|
|
||||||
switch_on[g.name, t] = (t == 1 ? 1.0 - _is_initially_on(g) : 0.0)
|
|
||||||
switch_off[g.name, t] = 0.0
|
|
||||||
else
|
|
||||||
is_on[g.name, t] = @variable(model, binary = true)
|
is_on[g.name, t] = @variable(model, binary = true)
|
||||||
switch_on[g.name, t] = @variable(model, binary = true)
|
switch_on[g.name, t] = @variable(model, binary = true)
|
||||||
switch_off[g.name, t] = @variable(model, binary = true)
|
switch_off[g.name, t] = @variable(model, binary = true)
|
||||||
|
|
||||||
|
# Use initial conditions and whether a unit must run to fix variables
|
||||||
|
if FIX_VARS
|
||||||
|
# Fix variables using fix function
|
||||||
|
if g.must_run[t]
|
||||||
|
# If the generator _must_ run, then it is obviously on and cannot be switched off
|
||||||
|
# In the first time period, force unit to switch on if was off before
|
||||||
|
# Otherwise, unit is on, and will never turn off, so will never need to turn on
|
||||||
|
fix(is_on[g.name, t], 1.0; force = true)
|
||||||
|
fix(
|
||||||
|
switch_on[g.name, t],
|
||||||
|
(t == 1 ? 1.0 - _is_initially_on(g) : 0.0);
|
||||||
|
force = true,
|
||||||
|
)
|
||||||
|
fix(switch_off[g.name, t], 0.0; force = true)
|
||||||
|
elseif t == 1
|
||||||
|
if is_initially_on
|
||||||
|
# Generator was on (for g.initial_status time periods),
|
||||||
|
# so cannot be more switched on until the period after the first time it can be turned off
|
||||||
|
fix(switch_on[g.name, 1], 0.0; force = true)
|
||||||
|
else
|
||||||
|
# Generator is initially off (for -g.initial_status time periods)
|
||||||
|
# Cannot be switched off more
|
||||||
|
fix(switch_off[g.name, 1], 0.0; force = true)
|
||||||
|
end
|
||||||
|
end
|
||||||
|
else
|
||||||
|
# Add explicit constraint if !FIX_VARS
|
||||||
|
if g.must_run[t]
|
||||||
|
is_on[g.name, t] = 1.0
|
||||||
|
switch_on[g.name, t] =
|
||||||
|
(t == 1 ? 1.0 - _is_initially_on(g) : 0.0)
|
||||||
|
switch_off[g.name, t] = 0.0
|
||||||
|
elseif t == 1
|
||||||
|
if is_initially_on
|
||||||
|
switch_on[g.name, t] = 0.0
|
||||||
|
else
|
||||||
|
switch_off[g.name, t] = 0.0
|
||||||
|
end
|
||||||
|
end
|
||||||
|
end
|
||||||
|
|
||||||
|
# Use initial conditions and whether a unit must run to fix variables
|
||||||
|
if FIX_VARS
|
||||||
|
# Fix variables using fix function
|
||||||
|
if g.must_run[t]
|
||||||
|
# If the generator _must_ run, then it is obviously on and cannot be switched off
|
||||||
|
# In the first time period, force unit to switch on if was off before
|
||||||
|
# Otherwise, unit is on, and will never turn off, so will never need to turn on
|
||||||
|
fix(is_on[g.name, t], 1.0; force = true)
|
||||||
|
fix(
|
||||||
|
switch_on[g.name, t],
|
||||||
|
(t == 1 ? 1.0 - _is_initially_on(g) : 0.0);
|
||||||
|
force = true,
|
||||||
|
)
|
||||||
|
fix(switch_off[g.name, t], 0.0; force = true)
|
||||||
|
elseif t == 1
|
||||||
|
if is_initially_on
|
||||||
|
# Generator was on (for g.initial_status time periods),
|
||||||
|
# so cannot be more switched on until the period after the first time it can be turned off
|
||||||
|
fix(switch_on[g.name, 1], 0.0; force = true)
|
||||||
|
else
|
||||||
|
# Generator is initially off (for -g.initial_status time periods)
|
||||||
|
# Cannot be switched off more
|
||||||
|
fix(switch_off[g.name, 1], 0.0; force = true)
|
||||||
|
end
|
||||||
|
end
|
||||||
|
else
|
||||||
|
# Add explicit constraint if !FIX_VARS
|
||||||
|
if g.must_run[t]
|
||||||
|
is_on[g.name, t] = 1.0
|
||||||
|
switch_on[g.name, t] =
|
||||||
|
(t == 1 ? 1.0 - _is_initially_on(g) : 0.0)
|
||||||
|
switch_off[g.name, t] = 0.0
|
||||||
|
elseif t == 1
|
||||||
|
if is_initially_on
|
||||||
|
switch_on[g.name, t] = 0.0
|
||||||
|
else
|
||||||
|
switch_off[g.name, t] = 0.0
|
||||||
|
end
|
||||||
|
end
|
||||||
end
|
end
|
||||||
end
|
end
|
||||||
return
|
return
|
||||||
|
|||||||
@@ -17,8 +17,53 @@ import ..PiecewiseLinearCostsFormulation
|
|||||||
import ..ProductionVarsFormulation
|
import ..ProductionVarsFormulation
|
||||||
import ..StatusVarsFormulation
|
import ..StatusVarsFormulation
|
||||||
|
|
||||||
|
"""
|
||||||
|
Variables
|
||||||
|
---
|
||||||
|
* `prod_above`:
|
||||||
|
[gen, t];
|
||||||
|
*production above minimum required level*;
|
||||||
|
lb: 0, ub: Inf.
|
||||||
|
KnuOstWat2020: `p'_g(t)`
|
||||||
|
* `segprod`:
|
||||||
|
[gen, segment, t];
|
||||||
|
*how much generator produces on cost segment in time t*;
|
||||||
|
lb: 0, ub: Inf.
|
||||||
|
KnuOstWat2020: `p_g^l(t)`
|
||||||
|
"""
|
||||||
struct ProdVars <: ProductionVarsFormulation end
|
struct ProdVars <: ProductionVarsFormulation end
|
||||||
|
|
||||||
struct PwlCosts <: PiecewiseLinearCostsFormulation end
|
struct PwlCosts <: PiecewiseLinearCostsFormulation end
|
||||||
struct StatusVars <: StatusVarsFormulation end
|
|
||||||
|
"""
|
||||||
|
Variables
|
||||||
|
---
|
||||||
|
* `is_on`:
|
||||||
|
[gen, t];
|
||||||
|
*is generator on at time t?*
|
||||||
|
lb: 0, ub: 1, binary.
|
||||||
|
KnuOstWat2020: `u_g(t)`
|
||||||
|
* `switch_on`:
|
||||||
|
[gen, t];
|
||||||
|
*indicator that generator will be turned on at t*;
|
||||||
|
lb: 0, ub: 1, binary.
|
||||||
|
KnuOstWat2020: `v_g(t)`
|
||||||
|
* `switch_off`: binary;
|
||||||
|
[gen, t];
|
||||||
|
*indicator that generator will be turned off at t*;
|
||||||
|
lb: 0, ub: 1, binary.
|
||||||
|
KnuOstWat2020: `w_g(t)`
|
||||||
|
|
||||||
|
Arguments
|
||||||
|
---
|
||||||
|
* `fix_vars_via_constraint`:
|
||||||
|
indicator for whether to set vars to a constant using `fix` or by adding an explicit constraint
|
||||||
|
(particulary useful for debugging purposes).
|
||||||
|
"""
|
||||||
|
struct StatusVars <: StatusVarsFormulation
|
||||||
|
fix_vars_via_constraint::Bool
|
||||||
|
|
||||||
|
StatusVars() = new(false)
|
||||||
|
end
|
||||||
|
|
||||||
end
|
end
|
||||||
|
|||||||
@@ -4,15 +4,11 @@
|
|||||||
|
|
||||||
function _add_bus!(model::JuMP.Model, b::Bus)::Nothing
|
function _add_bus!(model::JuMP.Model, b::Bus)::Nothing
|
||||||
net_injection = _init(model, :expr_net_injection)
|
net_injection = _init(model, :expr_net_injection)
|
||||||
reserve = _init(model, :expr_reserve)
|
|
||||||
curtail = _init(model, :curtail)
|
curtail = _init(model, :curtail)
|
||||||
for t in 1:model[:instance].time
|
for t in 1:model[:instance].time
|
||||||
# Fixed load
|
# Fixed load
|
||||||
net_injection[b.name, t] = AffExpr(-b.load[t])
|
net_injection[b.name, t] = AffExpr(-b.load[t])
|
||||||
|
|
||||||
# Reserves
|
|
||||||
reserve[b.name, t] = AffExpr()
|
|
||||||
|
|
||||||
# Load curtailment
|
# Load curtailment
|
||||||
curtail[b.name, t] =
|
curtail[b.name, t] =
|
||||||
@variable(model, lower_bound = 0, upper_bound = b.load[t])
|
@variable(model, lower_bound = 0, upper_bound = b.load[t])
|
||||||
|
|||||||
@@ -29,13 +29,28 @@ end
|
|||||||
|
|
||||||
function _add_reserve_eqs!(model::JuMP.Model)::Nothing
|
function _add_reserve_eqs!(model::JuMP.Model)::Nothing
|
||||||
eq_min_reserve = _init(model, :eq_min_reserve)
|
eq_min_reserve = _init(model, :eq_min_reserve)
|
||||||
for t in 1:model[:instance].time
|
instance = model[:instance]
|
||||||
|
for t in 1:instance.time
|
||||||
|
# Equation (68) in Kneuven et al. (2020)
|
||||||
|
# As in Morales-España et al. (2013a)
|
||||||
|
# Akin to the alternative formulation with max_power_avail
|
||||||
|
# from Carrión and Arroyo (2006) and Ostrowski et al. (2012)
|
||||||
|
shortfall_penalty = instance.shortfall_penalty[t]
|
||||||
eq_min_reserve[t] = @constraint(
|
eq_min_reserve[t] = @constraint(
|
||||||
model,
|
model,
|
||||||
sum(
|
sum(model[:reserve][g.name, t] for g in instance.units) +
|
||||||
model[:expr_reserve][b.name, t] for b in model[:instance].buses
|
(shortfall_penalty >= 0 ? model[:reserve_shortfall][t] : 0.0) >=
|
||||||
) >= model[:instance].reserves.spinning[t]
|
instance.reserves.spinning[t]
|
||||||
)
|
)
|
||||||
|
|
||||||
|
# Account for shortfall contribution to objective
|
||||||
|
if shortfall_penalty >= 0
|
||||||
|
add_to_expression!(
|
||||||
|
model[:obj],
|
||||||
|
shortfall_penalty,
|
||||||
|
model[:reserve_shortfall][t],
|
||||||
|
)
|
||||||
|
end
|
||||||
end
|
end
|
||||||
return
|
return
|
||||||
end
|
end
|
||||||
|
|||||||
@@ -2,6 +2,15 @@
|
|||||||
# Copyright (C) 2020, UChicago Argonne, LLC. All rights reserved.
|
# Copyright (C) 2020, UChicago Argonne, LLC. All rights reserved.
|
||||||
# Released under the modified BSD license. See COPYING.md for more details.
|
# Released under the modified BSD license. See COPYING.md for more details.
|
||||||
|
|
||||||
|
"""
|
||||||
|
_add_unit!(model::JuMP.Model, g::Unit, formulation::Formulation)
|
||||||
|
|
||||||
|
Add production, reserve, startup, shutdown, and status variables,
|
||||||
|
and constraints for min uptime/downtime, net injection, production, ramping, startup, shutdown, and status.
|
||||||
|
|
||||||
|
Fix variables if a certain generator _must_ run or if a generator provides spinning reserves.
|
||||||
|
Also, add overflow penalty to objective for each transmission line.
|
||||||
|
"""
|
||||||
function _add_unit!(model::JuMP.Model, g::Unit, formulation::Formulation)
|
function _add_unit!(model::JuMP.Model, g::Unit, formulation::Formulation)
|
||||||
if !all(g.must_run) && any(g.must_run)
|
if !all(g.must_run) && any(g.must_run)
|
||||||
error("Partially must-run units are not currently supported")
|
error("Partially must-run units are not currently supported")
|
||||||
@@ -35,7 +44,12 @@ function _add_unit!(model::JuMP.Model, g::Unit, formulation::Formulation)
|
|||||||
formulation.status_vars,
|
formulation.status_vars,
|
||||||
)
|
)
|
||||||
_add_startup_cost_eqs!(model, g, formulation.startup_costs)
|
_add_startup_cost_eqs!(model, g, formulation.startup_costs)
|
||||||
_add_startup_shutdown_limit_eqs!(model, g)
|
_add_startup_shutdown_limit_eqs!(
|
||||||
|
model,
|
||||||
|
g,
|
||||||
|
formulation.status_vars,
|
||||||
|
formulation.prod_vars,
|
||||||
|
)
|
||||||
_add_status_eqs!(model, g, formulation.status_vars)
|
_add_status_eqs!(model, g, formulation.status_vars)
|
||||||
return
|
return
|
||||||
end
|
end
|
||||||
@@ -44,12 +58,16 @@ _is_initially_on(g::Unit)::Float64 = (g.initial_status > 0 ? 1.0 : 0.0)
|
|||||||
|
|
||||||
function _add_reserve_vars!(model::JuMP.Model, g::Unit)::Nothing
|
function _add_reserve_vars!(model::JuMP.Model, g::Unit)::Nothing
|
||||||
reserve = _init(model, :reserve)
|
reserve = _init(model, :reserve)
|
||||||
|
reserve_shortfall = _init(model, :reserve_shortfall)
|
||||||
for t in 1:model[:instance].time
|
for t in 1:model[:instance].time
|
||||||
if g.provides_spinning_reserves[t]
|
if g.provides_spinning_reserves[t]
|
||||||
reserve[g.name, t] = @variable(model, lower_bound = 0)
|
reserve[g.name, t] = @variable(model, lower_bound = 0)
|
||||||
else
|
else
|
||||||
reserve[g.name, t] = 0.0
|
reserve[g.name, t] = 0.0
|
||||||
end
|
end
|
||||||
|
reserve_shortfall[t] =
|
||||||
|
(model[:instance].shortfall_penalty[t] >= 0) ?
|
||||||
|
@variable(model, lower_bound = 0) : 0.0
|
||||||
end
|
end
|
||||||
return
|
return
|
||||||
end
|
end
|
||||||
@@ -72,7 +90,22 @@ function _add_startup_shutdown_vars!(model::JuMP.Model, g::Unit)::Nothing
|
|||||||
return
|
return
|
||||||
end
|
end
|
||||||
|
|
||||||
function _add_startup_shutdown_limit_eqs!(model::JuMP.Model, g::Unit)::Nothing
|
"""
|
||||||
|
_add_startup_shutdown_limit_eqs!(model::JuMP.Model, g::Unit)::Nothing
|
||||||
|
|
||||||
|
Creates startup/shutdown limit constraints below based on variables `Gar1962.StatusVars`, `prod_above` from `Gar1962.ProdVars`, and `reserve`.
|
||||||
|
|
||||||
|
Constraints
|
||||||
|
---
|
||||||
|
* :eq_startup_limit
|
||||||
|
* :eq_shutdown_limit
|
||||||
|
"""
|
||||||
|
function _add_startup_shutdown_limit_eqs!(
|
||||||
|
model::JuMP.Model,
|
||||||
|
g::Unit,
|
||||||
|
formulation_status_vars::Gar1962.StatusVars,
|
||||||
|
formulation_prod_vars::Gar1962.ProdVars,
|
||||||
|
)::Nothing
|
||||||
eq_shutdown_limit = _init(model, :eq_shutdown_limit)
|
eq_shutdown_limit = _init(model, :eq_shutdown_limit)
|
||||||
eq_startup_limit = _init(model, :eq_startup_limit)
|
eq_startup_limit = _init(model, :eq_startup_limit)
|
||||||
is_on = model[:is_on]
|
is_on = model[:is_on]
|
||||||
@@ -91,8 +124,15 @@ function _add_startup_shutdown_limit_eqs!(model::JuMP.Model, g::Unit)::Nothing
|
|||||||
)
|
)
|
||||||
# Shutdown limit
|
# Shutdown limit
|
||||||
if g.initial_power > g.shutdown_limit
|
if g.initial_power > g.shutdown_limit
|
||||||
|
# TODO check what happens with these variables when exporting the model
|
||||||
|
# Generator producing too much to be turned off in the first time period
|
||||||
|
# (can a binary variable have bounds x = 0?)
|
||||||
|
if formulation_status_vars.fix_vars_via_constraint
|
||||||
eq_shutdown_limit[g.name, 0] =
|
eq_shutdown_limit[g.name, 0] =
|
||||||
@constraint(model, switch_off[g.name, 1] <= 0)
|
@constraint(model, model[:switch_off][g.name, 1] <= 0.0)
|
||||||
|
else
|
||||||
|
fix(model[:switch_off][g.name, 1], 0.0; force = true)
|
||||||
|
end
|
||||||
end
|
end
|
||||||
if t < T
|
if t < T
|
||||||
eq_shutdown_limit[g.name, t] = @constraint(
|
eq_shutdown_limit[g.name, t] = @constraint(
|
||||||
@@ -210,11 +250,5 @@ function _add_net_injection_eqs!(model::JuMP.Model, g::Unit)::Nothing
|
|||||||
model[:is_on][g.name, t],
|
model[:is_on][g.name, t],
|
||||||
g.min_power[t],
|
g.min_power[t],
|
||||||
)
|
)
|
||||||
# Add to reserves expression
|
|
||||||
add_to_expression!(
|
|
||||||
model[:expr_reserve][g.bus.name, t],
|
|
||||||
model[:reserve][g.name, t],
|
|
||||||
1.0,
|
|
||||||
)
|
|
||||||
end
|
end
|
||||||
end
|
end
|
||||||
|
|||||||
@@ -51,6 +51,12 @@ function solution(model::JuMP.Model)::OrderedDict
|
|||||||
sol["Switch on"] = timeseries(model[:switch_on], instance.units)
|
sol["Switch on"] = timeseries(model[:switch_on], instance.units)
|
||||||
sol["Switch off"] = timeseries(model[:switch_off], instance.units)
|
sol["Switch off"] = timeseries(model[:switch_off], instance.units)
|
||||||
sol["Reserve (MW)"] = timeseries(model[:reserve], instance.units)
|
sol["Reserve (MW)"] = timeseries(model[:reserve], instance.units)
|
||||||
|
sol["Reserve shortfall (MW)"] = OrderedDict(
|
||||||
|
t =>
|
||||||
|
(instance.shortfall_penalty[t] >= 0) ?
|
||||||
|
round(value(model[:reserve_shortfall][t]), digits = 5) : 0.0 for
|
||||||
|
t in 1:instance.time
|
||||||
|
)
|
||||||
sol["Net injection (MW)"] =
|
sol["Net injection (MW)"] =
|
||||||
timeseries(model[:net_injection], instance.buses)
|
timeseries(model[:net_injection], instance.buses)
|
||||||
sol["Load curtail (MW)"] = timeseries(model[:curtail], instance.buses)
|
sol["Load curtail (MW)"] = timeseries(model[:curtail], instance.buses)
|
||||||
|
|||||||
@@ -324,11 +324,16 @@ function _validate_reserve_and_demand(instance, solution, tol = 0.01)
|
|||||||
# Verify spinning reserves
|
# Verify spinning reserves
|
||||||
reserve =
|
reserve =
|
||||||
sum(solution["Reserve (MW)"][g.name][t] for g in instance.units)
|
sum(solution["Reserve (MW)"][g.name][t] for g in instance.units)
|
||||||
if reserve < instance.reserves.spinning[t] - tol
|
reserve_shortfall =
|
||||||
|
(instance.shortfall_penalty[t] >= 0) ?
|
||||||
|
solution["Reserve shortfall (MW)"][t] : 0
|
||||||
|
|
||||||
|
if reserve + reserve_shortfall < instance.reserves.spinning[t] - tol
|
||||||
@error @sprintf(
|
@error @sprintf(
|
||||||
"Insufficient spinning reserves at time %d (%.2f should be %.2f)",
|
"Insufficient spinning reserves at time %d (%.2f + %.2f should be %.2f)",
|
||||||
t,
|
t,
|
||||||
reserve,
|
reserve,
|
||||||
|
reserve_shortfall,
|
||||||
instance.reserves.spinning[t],
|
instance.reserves.spinning[t],
|
||||||
)
|
)
|
||||||
err_count += 1
|
err_count += 1
|
||||||
|
|||||||
@@ -20,8 +20,14 @@ if ENABLE_LARGE_TESTS
|
|||||||
end
|
end
|
||||||
|
|
||||||
function _small_test(formulation::Formulation)::Nothing
|
function _small_test(formulation::Formulation)::Nothing
|
||||||
instance = UnitCommitment.read_benchmark("matpower/case118/2017-02-01")
|
instances = ["matpower/case118/2017-02-01", "test/case14"]
|
||||||
UnitCommitment.build_model(instance = instance, formulation = formulation) # should not crash
|
for instance in instances
|
||||||
|
# Should not crash
|
||||||
|
UnitCommitment.build_model(
|
||||||
|
instance = UnitCommitment.read_benchmark(instance),
|
||||||
|
formulation = formulation,
|
||||||
|
)
|
||||||
|
end
|
||||||
return
|
return
|
||||||
end
|
end
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue
Block a user