# UnitCommitment.jl: Optimization Package for Security-Constrained Unit Commitment
|
|
# Copyright (C) 2020, UChicago Argonne, LLC. All rights reserved.
|
|
# Released under the modified BSD license. See COPYING.md for more details.
|
|
|
|
using UnitCommitment, DataStructures, HiGHS
|
|
import UnitCommitment: TimeDecomposition, ConventionalLMP
|
|
|
|
function solution_methods_TimeDecomposition_optimize_test()
|
|
@testset "optimize_time_decomposition" begin
|
|
# read one scenario
|
|
instance = UnitCommitment.read(fixture("case14.json.gz"))
|
|
solution = UnitCommitment.optimize!(
|
|
instance,
|
|
TimeDecomposition(time_window = 3, time_increment = 2),
|
|
optimizer = optimizer_with_attributes(
|
|
HiGHS.Optimizer,
|
|
"log_to_console" => false,
|
|
),
|
|
)
|
|
@test length(solution["Thermal production (MW)"]["g1"]) == 4
|
|
@test length(solution["Is on"]["g2"]) == 4
|
|
@test length(solution["Spinning reserve (MW)"]["r1"]["g2"]) == 4
|
|
|
|
# read one scenario with after_build and after_optimize
|
|
function after_build(model, instance)
|
|
@constraint(
|
|
model,
|
|
model[:is_on]["g3", 1] + model[:is_on]["g4", 1] <= 1,
|
|
)
|
|
end
|
|
|
|
lmps = []
|
|
function after_optimize(solution, model, instance)
|
|
lmp = UnitCommitment.compute_lmp(
|
|
model,
|
|
ConventionalLMP(),
|
|
optimizer = optimizer_with_attributes(
|
|
HiGHS.Optimizer,
|
|
"log_to_console" => false,
|
|
),
|
|
)
|
|
return push!(lmps, lmp)
|
|
end
|
|
|
|
instance = UnitCommitment.read(fixture("case14-profiled.json.gz"))
|
|
solution = UnitCommitment.optimize!(
|
|
instance,
|
|
TimeDecomposition(time_window = 3, time_increment = 2),
|
|
optimizer = optimizer_with_attributes(
|
|
HiGHS.Optimizer,
|
|
"log_to_console" => false,
|
|
),
|
|
after_build = after_build,
|
|
after_optimize = after_optimize,
|
|
)
|
|
@test length(lmps) == 2
|
|
@test lmps[1]["s1", "b1", 1] == 50.0
|
|
@test lmps[2]["s1", "b10", 2] ≈ 38.04 atol = 0.1
|
|
@test solution["Is on"]["g3"][1] == 1.0
|
|
@test solution["Is on"]["g4"][1] == 0.0
|
|
|
|
# read multiple scenarios
|
|
instance = UnitCommitment.read([
|
|
fixture("case14.json.gz"),
|
|
fixture("case14-profiled.json.gz"),
|
|
])
|
|
solution = UnitCommitment.optimize!(
|
|
instance,
|
|
TimeDecomposition(time_window = 3, time_increment = 2),
|
|
optimizer = optimizer_with_attributes(
|
|
HiGHS.Optimizer,
|
|
"log_to_console" => false,
|
|
),
|
|
)
|
|
@test length(solution["case14"]["Thermal production (MW)"]["g3"]) == 4
|
|
@test length(solution["case14"]["Is on"]["g4"]) == 4
|
|
@test length(
|
|
solution["case14-profiled"]["Thermal production (MW)"]["g5"],
|
|
) == 4
|
|
@test length(solution["case14-profiled"]["Is on"]["g6"]) == 4
|
|
@test length(
|
|
solution["case14-profiled"]["Profiled production (MW)"]["g7"],
|
|
) == 4
|
|
@test length(
|
|
solution["case14-profiled"]["Spinning reserve (MW)"]["r1"]["g3"],
|
|
) == 4
|
|
end
|
|
end
|