function res=calCPF(SysData,options,caseName,varargin) % % FUNCTION calCPF % % Function for calculating continuation power flow % Author: Rui Yao % % Copyright (C) 2021, UChicago Argonne, LLC. All rights reserved. % % OPEN SOURCE LICENSE % % Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: % % 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. % 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. % 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. % % % ****************************************************************************************************** % DISCLAIMER % % THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED % WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A % PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY % DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, % PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER % CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR % OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. % *************************************************************************************************** % res=[]; simSettings=getDefaultSimSettings(); if nargin<2 options=regulateOptions(); else options=regulateOptions(options); end if nargin<3||isempty(caseName) caseName=['d_~',num2str(size(SysData.bus,1))]; end nVarargs=length(varargin); if nVarargs<1 ME=MException('PowerSAS:invalidArgument','CPF should have arguments specifying load increase direction.'); throw(ME); else zipRamp=[]; pvRamp=[]; if nVarargs>=1 zipRamp=varargin{1}; end if nVarargs>=2 pvRamp=varargin{2}; end if nVarargs>=3 snapshot=varargin{3}; hotStart=1; else snapshot=[]; hotStart=0; end if options.method==4 simSettings.eventList(1,6) = 4; simSettings.eventList=[simSettings.eventList;[2 0.0000 options.simLen 50 1 4.0 0.0000]]; else simSettings.eventList=[simSettings.eventList;[2 0.0000 options.simLen 50 1 0.0 0.0000]]; end simSettings.evtDynZipRamp=zipRamp; simSettings.evtDynPV=pvRamp; simSettings.evtDyn=zeros(1,23); simSettings.evtDyn(1,1)=1; simSettings.evtDyn(1,4)=1; simSettings.evtDyn(1,5)=size(pvRamp,1); simSettings.evtDyn(1,12)=1; simSettings.evtDyn(1,13)=size(zipRamp,1); options.hotStart=hotStart; res=runDynamicSimulationExec(caseName,SysData,simSettings,options,snapshot); end end function options=regulateOptions(options) if nargin<1 options=[]; end if ~isfield(options,'nlvl');options.nlvl=15;end if ~isfield(options,'taylorN');options.taylorN=4;end if ~isfield(options,'segAlpha');options.segAlpha=1;end if ~isfield(options,'dAlpha');options.dAlpha=1;end if ~isfield(options,'alphaTol');options.alphaTol=1e-3;end if ~isfield(options,'diffTol');options.diffTol=1e-6;end if ~isfield(options,'diffTolMax');options.diffTolMax=1e-2;end if ~isfield(options,'method');options.method=0;end if ~isfield(options,'simLen');options.simLen=200;end if ~isfield(options,'diffTolCtrl');options.diffTolCtrl=1e-5;end if ~isfield(options,'useNoMoveCtrl');options.useNoMoveCtrl=1;end if ~isfield(options,'Efstd');options.Efstd=1.2;end end