function [Base, w, FtBus, time_step, time_step_on, TimeRange1, FtTime, TotalTime, TimeRange2, TimeRange3] = set_simulation_parameters()
|
|
% This function sets the simulation parameters.
|
|
|
|
%% settings
|
|
Base = 100; % baseMVA
|
|
w = 120*pi;
|
|
FtBus = 7; % grounding fault bus
|
|
time_step = 1*10^(-6); % pre and post fault
|
|
% time_step_on = 2*10^(-8); % during fault
|
|
time_step_on = 1*10^(-6); % during fault
|
|
TimeRange1 = [0,0.1]; % pre-fault simulation time (second)
|
|
FtTime = 5/60; % Fault lasting time (second) (5/60 is five cycles)
|
|
TotalTime = 0.5; %1; % Total simulation time (second)
|
|
TimeRange2 = [TimeRange1(2),TimeRange1(2)+FtTime]; % fault-on simulation period
|
|