You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
powersas.m/data/setting_039_1.m

171 lines
3.6 KiB

% Event definition for 39-bus system
% Author: Rui Yao <ruiyao@ieee.org>
%
% Copyright (C) 2021, UChicago Argonne, LLC. All rights reserved.
%
% OPEN SOURCE LICENSE
%
% Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
%
% 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
% 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
% 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.
%
%
% ******************************************************************************************************
% DISCLAIMER
%
% THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
% WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
% PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY
% DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
% PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
% CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
% OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
% ***************************************************************************************************
%
%
nlvl = 15;
taylorN = 4;
alphaTol =1.0000e-03;
diffTol =1.0000e-06;
diffTolMax =1.0000e-02;
method=0;
diffTolCtrl=2e-6;
% evtId, startTime, endTime, type, num
% Type:
% 0: Black start / Full start (steady state)
% 1: Add line
% 2: Add static load
% 3: Add Motor load
% 4: Add syn gen
% 50: Dyn simulation
% 6: Fault
% 7: Cut line
% 8: Cut static load
% 9: Cut Motor load
% 10: Cut syn gen
% 99: End of simulation
% Method: X.Y
% Method X: Differential eq.
% 0:HE, 1:Modified Euler, 2:RK-4, 3: TRAP.
% Method Y: Algebraic eq. 0:HE, 1:N-R.
eventList=[...
1 0.0000 0.0000 0 1
1.1 1.5000 0.0000 6 1
1.2 1.6700 0.0000 6 2
% 1.3 1.5000 4.0000 50 1
2 5.000 0.0000 99 0
];
% Blackstart data
bsSyn=[...
];
bsBus=[...
];
bsInd=[...
];
% Plain start data
Efstd=[...
1.1922
1.2157
1.2140
1.2213
1.2137
1.2444
1.2607
1.2887
1.3101
1.3264
];
% Line event data
evtLine=[...
];
evtLineSpec=[...
];
% Static load event data
evtZip=[...
];
evtZipSpec=[...
];
evtZipSpec2=[...
];
% Motor load event data
evtInd=[...
];
evtIndSpec=[...
];
% Syncronous generator event data
evtSyn=[...
];
evtSynSpec=[...
];
% Fault event data
evtFault=[...
1 1 1
2 2 2
];
evtFaultSpec=[...
14, 0.00, 0, 0.013, 0;
14, 0.00, 0, 0.013, 1;
];
% Dynamic simulation event data
evtDyn=[...
1 0 0 0 0 0 0 0 0 0 0 0 0 1 2 1 2 0 0 0 0 0 0
];
evtDynPQ=[...
];
evtDynPV=[...
];
evtDynInd=[...
];
evtDynZip=[...
];
evtDynSh=[...
];
evtDynZipRamp=[...
];
evtDynTmech=[...
1 0.3459
2 -0.3459
];
evtDynPm=[...
1 0.3459
2 -0.3459
];
evtDynEf=[...
];
evtDynVref=[...
];
evtDynEq1=[...
];