You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

81 lines
2.5 KiB

function mpc = kundur
%KUNDUR
% PSS(R)E 32 RAW created by rawd32 THU, JAN 30 2020 10:51
% MODIFIED KUNDUR'S TWO-AREA TEST SYSTEM, DISTRIBUTED WITH ANDES
% SEE THE BOOK "POWER SYSTEM STABILITY AND CONTROL" FOR ORIGINAL DATA
%
% Converted by MATPOWER 7.1 using PSSE2MPC on 16-Mar-2023
% from 'kundur.raw' using PSS/E rev 32 format.
%
% WARNINGS:
% Skipped 1 line of zone data.
% Skipped 1 line of owner data.
% Using default voltage magnitude limits: VMIN = 0.9 p.u., VMAX = 1.1 p.u.
%
% See CASEFORMAT for details on the MATPOWER case file format.
%% MATPOWER Case Format : Version 2
mpc.version = '2';
%%----- Power Flow Data -----%%
%% system MVA base
mpc.baseMVA = 100;
%% bus data
% bus_i type Pd Qd Gs Bs area Vm Va baseKV zone Vmax Vmin
mpc.bus = [
1 3 0 0 0 0 1 1 32.6732 20 1 1.1 0.9;
2 2 0 0 0 0 1 1 21.6548 20 1 1.1 0.9;
3 2 0 0 0 0 2 1 11.2148 20 1 1.1 0.9;
4 2 0 0 0 0 2 1 21.6398 20 1 1.1 0.9;
5 1 0 0 0 0 1 0.98337 27.6488 230 1 1.1 0.9;
6 1 0 0 0 0 1 0.96908 16.8176 230 1 1.1 0.9;
7 1 1159 -73.5 0 0 1 0.95621 8.1662 230 1 1.1 0.9;
8 1 1575 -89.9 0 0 2 0.954 -2.1295 230 1 1.1 0.9;
9 1 0 0 0 0 2 0.96856 6.3774 230 1 1.1 0.9;
10 1 0 0 0 0 2 0.98377 16.8036 230 1 1.1 0.9;
];
%% generator data
% bus Pg Qg Qmax Qmin Vg mBase status Pmax Pmin Pc1 Pc2 Qc1min Qc1max Qc2min Qc2max ramp_agc ramp_10 ramp_30 ramp_q apf
mpc.gen = [
1 745.861 143.612 600 0 1 900 1 900 0 0 0 0 0 0 0 0 0 0 0 0;
2 700 300 600 -600 1 900 1 900 0 0 0 0 0 0 0 0 0 0 0 0;
3 700 550 600 -600 1 900 1 900 0 0 0 0 0 0 0 0 0 0 0 0;
4 700 -100 600 -600 1 900 1 900 0 0 0 0 0 0 0 0 0 0 0 0;
];
%% branch data
% fbus tbus r x b rateA rateB rateC ratio angle status angmin angmax
mpc.branch = [
5 6 0.005 0.05 0.075 0 0 0 0 0 1 -360 360;
5 6 0.00501 0.05001 0.075 0 0 0 0 0 1 -360 360;
6 7 0.002 0.02 0.03 0 0 0 0 0 1 -360 360;
6 7 0.00201 0.02001 0.03 0 0 0 0 0 1 -360 360;
7 8 0.02201 0.22001 0.33 0 0 0 0 0 1 -360 360;
7 8 0.02202 0.22002 0.33 0 0 0 0 0 1 -360 360;
7 8 0.022 0.22 0.33 0 0 0 0 0 1 -360 360;
8 9 0.002 0.02 0.03 0 0 0 0 0 1 -360 360;
8 9 0.00201 0.02001 0.03 0 0 0 0 0 1 -360 360;
9 10 0.005 0.05 0.075 0 0 0 0 0 1 -360 360;
9 10 0.00501 0.05001 0.075 0 0 0 0 0 1 -360 360;
1 5 0.001 0.012 0 0 0 0 1 0 1 -360 360;
2 6 0.001 0.012 0 0 0 0 1 0 1 -360 360;
3 9 0.001 0.012 0 0 0 0 1 0 1 -360 360;
4 10 0.001 0.012 0 0 0 0 1 0 1 -360 360;
];
%% bus names
mpc.bus_name = {
'1 ';
'2 ';
'12 ';
'11 ';
'101 ';
'102 ';
'3 ';
'13 ';
'112 ';
'111 ';
};