% EXAMPLE: extended-term simulation
|
|
%
|
|
% in Software PowerSAS.m
|
|
% Author: Rui Yao <ruiyao@ieee.org>
|
|
%
|
|
% Copyright (C) 2021, UChicago Argonne, LLC. All rights reserved.
|
|
%
|
|
% OPEN SOURCE LICENSE
|
|
%
|
|
% Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
|
|
%
|
|
% 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
|
|
% 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
|
|
% 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.
|
|
%
|
|
%
|
|
% ******************************************************************************************************
|
|
% DISCLAIMER
|
|
%
|
|
% THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
|
|
% WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
|
|
% PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY
|
|
% DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
|
|
% PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
|
|
% CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
|
|
% OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
% ***************************************************************************************************
|
|
|
|
clear; clc;
|
|
|
|
global Global_Settings
|
|
|
|
Global_Settings.logLevel='INFO';
|
|
|
|
% Full dynamic simulation
|
|
tagFullDynStart=tic;
|
|
res_004_fulldyn=runPowerSAS('dyn','d_004_2a_bs_agc.m',setOptions('allowSteadyDynSwitch',0),'settings_d_004_2a_agc');
|
|
timeFullDyn=toc(tagFullDynStart);
|
|
|
|
clc;
|
|
% Hybrid simulation with dynamic-QSS switching
|
|
tagHybridStart=tic;
|
|
res_004=runPowerSAS('dyn','d_004_2a_bs_agc.m',setOptions('allowSteadyDynSwitch',1),'settings_d_004_2a_agc');
|
|
timeHybrid=toc(tagHybridStart);
|
|
|
|
clc;
|
|
|
|
disp(['Full dynamic simulation computation time:', num2str(timeFullDyn),' s.']);
|
|
disp(['Hybrid simulation computation time:', num2str(timeHybrid),' s.']);
|
|
|
|
plotCurves(1,res_004_fulldyn.t,res_004_fulldyn.stateCurve,res_004_fulldyn.SysDataBase,'v');
|
|
plotCurves(2,res_004.t,res_004.stateCurve,res_004.SysDataBase,'v'); |